Transition Networks Network Card SPS 1872 CC User Manual

SPS-1872-CC (Conversion Center™)  
SPS-1872-DPS (Dual PointSystem™)  
SPS-1872-PS (PointSystem™)  
User’s Guide  
SPS-1872-xx  
External Power Supply  
18-60 VDC and 24-30 VRMS  
SPS-1872-SA (Stand-Alone)  
SPS-1872-SA  
SPS-1872-CC  
SPS-1872-DPS  
SPS-1872-PS  
The Transition Networks SPS-1872-xx external power supply provides a wide range  
of input power (18-60 VDC and 24-30 VRMS) to accommodate most industrial,  
telecom, and commercial applications. The SPS-1872-xx can deliver 12 watts of  
power, enough to power all Transition Networks stand-alone media converters as  
well as the single-slot (p/n CPSMC0100-20x) and the dual-slot (p/n CPSMC0200-2xx)  
chassis.  
The 18-60 VDC input allows for the installation of the SPS-1872-xx external power  
supply in all popular telecom, commercial, and industrial applications. The 24-30  
VRMS input allows for installation of the SPS-1872-xx in remaining industrial  
applications as well as HVAC and building control environments.  
The 'piggy-back' feature of the SPS-1872-CC, SPS-1872-PS, and SPS-1872-DPS  
allows it to physically attach to the media converter chassis and eliminate the power  
cable between the power supply and the media converter.  
Installation . . . . . . . . . . . . . . . . . .2  
Maintenance . . . . . . . . . . . . . . . .7  
Technical Specifications . . . . . . . .8  
Compliance Information . . . . . . .10  
Contact Us . . . . . . . . . . . . . . . . .11  
 
SPS1872-xx  
Installation -- Continued  
Installation -- Continued  
SPS-1872-CC (Conversion Center™)  
SPS-1872-DPS (Dual PointSystem™)  
1. Remove the left-rear and right-rear screws from the Conversion Center™  
1. Remove the left-rear and right-rear screws from the Dual PointSystem™  
media converter.  
media converter.  
2. Connect the barrel connector on the SPS-1872-CC to the power port of  
the media converter The flange of the SPS-1872-CC should slide over  
the rear of the media converter as the two devices are connected. The  
screw holes on the left and right sides should align.  
2. Connect the barrel connector on the SPS-1872-DPS to the power port of  
the media converter. The flange of the SPS-1872-DPS should slide over  
the rear of the media converter as the two devices are connected. The  
screw holes on the left and right sides should align.  
3. Secure the two devices together by replacing the two screws on either  
side of the SPS-1872-CC.  
3. Secure the two devices together by replacing the two screws on either  
side of the SPS-1872-DPS.  
TN Conversion Center  
media converter  
TN Dual PointSystem  
media converter  
SPS-1872-CC  
SPS-1872-DPS  
SPS-1872-PS (PointSystem™)  
1. Remove the left-rear and right-rear screws from the PointSystem™ media  
converter.  
2. Connect the barrel connector on the SPS-1872-PS to the power port of  
the media converter. The flange of the SPS-1872-PS should slide over the  
rear of the media converter as the two devices are connected. The screw  
holes on the left and right sides should align.  
3. Secure the two devices together by replacing the two screws on either  
side of the SPS-1872-PS.  
TN PointSystem  
media converter  
SPS-1872-PS  
24-Hour Technical Support: 800-260-1312 -- International: 952-941-7600  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
5
4
 
SPS-1872-xx  
Installation -- Continued  
Maintenance  
Supplying Power to the SPS-1872-xx  
Replacing the Fuse  
CAUTION: The power source MUST BE TURNED OFF when connecting it to  
the SPS-1872-xx external power supply. Failure to observe this caution could  
result in damage to, and subsequent failure of, the SPS-1872-xx and any attached  
device.  
CAUTION: The external power source MUST BE POWERED OFF when  
replacing the fuse to the SPS-1872-xx external power supply. Failure to observe  
this caution could result in damage to, and subsequent failure of, the SPS-1872-  
xx and any attached device.  
To supply power to the SPS-1872-xx:  
NOTE: Replace the fuse only with one of the same size and rating.  
1. Ensure that external power source is truned OFF.  
To replace the fuse in the SPS-1872-xx external power supply:  
1. Ensure that the external power source is turned OFF.  
2. Connect the positive (+) terminal of the power source to the positive  
terminal on the SPS-1872-xx (marked with a “3”). Turn the terminal  
screw clockwise to secure it.  
2. Remove and retain the four (4) screws that secure the cover to the SPS-  
1872-xx external power supply.  
3. Connect the negative (-) terminal of the power source to the negative  
terminal on the SPS-1872-xx (marked with a “2”). Turn the terminal  
screw clockwise to secure.  
3. Carefully lift the cover from the SPS-1872-xx.  
4. Locate the fuse on the SPS-1872-xx (see the picture below).  
4. Connect the ground terminal of the power source to the ground terminal  
on the SPS-1872-xx (marked with a “1”). Turn the terminal screw  
clockwise to secure.  
5. Power on the external power source.  
WARNING: The SPS1872 must be attached to a limited current circuit with a  
non-hazardous energy level of less than 240VA and be located in a restricted  
access area. Failure to observe this warning could result in an electrical shock.  
5. Carefully remove the fuse the from the fuse holder.  
6. Install a same size and rating replacement fuse in the fuse holder.  
7. Carefully slide the cover onto the SPS-1872-xx.  
1
2
3
INPUT  
POWER:  
SPS-1872-xx  
1
2
3
8. Replace the four (4) retained screws that secure the cover to the SPS-  
1872-xx.  
___  
___  
___  
-
+
9. Power on the external power source.  
GND  
-
+
External Power Source  
24-Hour Technical Support: 800-260-1312 -- International: 952-941-7600  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
7
6
 
SPS1872-xx  
Technical Specifications  
Technical Specifications -- Continued  
Input:  
For use with Transition Networks Model SPS-1872-xx or equivalent.  
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,  
Subchapter J applicable at the date of manufacture.  
Input Voltage  
18 - 60 VDC, 24 - 30 VRMS  
Isolation Voltage  
(Dielectric withstand) Meets IEC 950 for one minute  
1500 VAC: Output/Input  
Compliance  
UL listed EN60950; FCC & CISPR class A; CE Mark  
1500 VAC: Input/Safety GND  
1500 VAC: Output/Case  
Dimensions  
(length x width x height)  
SPS-1872-SA - 3.875 x 3.125 x 1.0 in (98 x 79 x 25 mm)  
SPS-1872-CC - 4.625 x 3.125 x 1.062 in (117 x 79 x 27 mm)  
SPS-1872-PS - 4.625 x 3.375 x 1.062 in (117 x 86 x 27 mm)  
SPS-1872-DPS - 4.625 x 3.375 x 1.75 in (117 x 86 x 45 mm)  
Output:  
Output Voltage  
Output Current  
Load Regulation  
Over Load Protection  
12.6 VDC  
Power Distribution  
Power Consumption  
Efficiency  
12.6 VDC at 1.0 A maximum  
6 W maximum @ 18 VDC input, 12.6 W output  
70 % (typical)  
1.0 A  
5% at 10% load to full-rated load  
(OLP) When the average power rating exceeds 125%-  
150% of the maximum power, the output voltage is  
reduced to a safe dissipation level. This action protects  
against output short circuit.  
Noise and Ripple  
MTBF  
40 mV peak-to-peak  
>290,000 hours Belcore with typical load at 50°C  
ambient temperature (calculated according to Belcore).  
>834,000 hours with typical load at 50°C ambient  
temperature (calculated according to MIL-HDBK-217F).  
No Load Operation  
Transient Protection  
No damage to power supply when operating at no load.  
No voltage spike at power-on, power-off, or power  
failure.  
Environment  
Warranty  
Tmra*:  
0 to 50°C (32 to 122° F )  
Storage Temp: -20 to 85°C  
Humidity:  
Altitude:  
5 to 95%, non condensing  
0 to 10,000 feet  
(*Manufacturer’s rated ambient temperature)  
Lifetime  
24-Hour Technical Support: 800-260-1312 -- International: 952-941-7600  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
9
8
 
SPS-1872-xx  
Contact Us  
Technical Support  
Compliance Information  
UL Listed  
Technical support is available 24 hours a day.  
C-UL Listed (Canada)  
CISPR/EN55022 Class A + EN55024  
FCC Regulations  
United States:  
International:  
1-800-260-1312  
00-1-952-941-7600  
This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated in a commercial  
environment. This equipment generates, uses, and can radiate radio frequency energy and, if  
not installed and used in accordance with the instruction manual, may cause harmful  
interference to radio communications. Operation of this equipment in a residential area is  
likely to cause harmful interference. In which case, the user will be required to correct the  
interference at the user’s own expense.  
Transition Now  
Chat live via the Web with Transition Networks Technical Support.  
Web-Based Seminars  
Transition Networks provides seminars via live web-based training.  
Log onto www.transition.com and click the Learning Center link.  
Canadian Regulations  
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus  
set out on the radio interference regulations of the Canadian Department of Communications.  
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites  
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le  
brouillage radioélectrique édicté par le ministère des Communications du Canada.  
E-Mail  
Ask a question anytime by sending an e-mail to our technical support staff.  
Address  
Transition Networks  
6475 City West Parkway  
Minneapolis, MN 55344, U.S.A.  
European Regulations  
Warning  
This is a Class A product. In a domestic environment this product may cause radio  
interference in which case the user may be required to take adequate measures.  
Achtung !  
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb  
dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für  
Gegenmaßnahmen verantwortlich.  
telephone:  
toll free:  
fax:  
952-941-7600  
800-526-9267  
952-941-2322  
Attention !  
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de  
créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les  
measures spécifiques appropriées.  
Declaration of Conformity  
In accordance with European Union Directive 2002/96/EC of the European  
Parliament and of the Council of 27 January 2003, Transition Networks will  
accept post usage returns of this product for proper disposal. The contact  
information for this activity can be found in the 'Contact Us' portion of this  
document.  
Name of Mfg:  
Transition Networks  
6475 City West Parkway, Minneapolis MN 55344 U.S.A.  
SPS-1872-xx External Power Supply  
SPS-1872-SA, SPS-1872-CC, SPS-1872-PS, SPS-1872-DPS  
EMC Directive 89/336/EEC  
Model:  
Part Number:  
Regulation:  
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE  
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in  
damage to the public telephone network.  
Purpose: To declare that the SPS-1872-xx to which this declaration refers is in  
conformity with the following standards.  
CISPR 22:1997+A1:2000; EN 55022:1998+A1:2000 Class A; FCC Part 15 subpart B;  
EN55024:1998; UL Listed  
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-  
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der  
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über  
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer  
Konformität.  
I, the undersigned, hereby declare that the equipment specified above conforms to the above  
Directive(s) and Standard(s).  
May 23, 2006_____  
Stephen Anderson, Vice-President of Engineering  
Date  
24-Hour Technical Support: 800-260-1312 -- International: 952-941-7600  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
11  
10  
 
Trademark Notice  
All trademarks and registered trademarks are the property of their respective owners.  
Copyright Restrictions  
© 2003, 2005 Transition Networks.  
All rights reserved. No part of this work may be reproduced or used in any form or by any  
means – graphic, electronic, or mechanical – without written permission from Transition  
Networks.  
Printed in the U.S.A.  
33266.E  
 

Technicolor Thomson CRT Television 14MS15GT User Manual
Teledyne Marine Instruments 465L User Manual
Toshiba Printer 7FM03281000 User Manual
Tricity Bendix Dishwasher BDW 46 User Manual
Tripp Lite Surge Protector LS604WM User Manual
Tyco Network Card DCM 150 User Manual
Uniden Cordless Telephone EXS 9650 User Manual
Vanguard Heating Gas Heater VN18 User Manual
Vornado Ventilation Hood AVH4 User Manual
Walker Indoor Furnishings W44CFDBL User Manual